      How do you know? In a typical solar system, you have to have a permit, which requires an inspector to come out and ensure everything is configured correctly and safely. These don’t require any permits, which is great for making them more affordable and accessible, but there’s also no one coming around to make sure that anyone is doing it safely.

      • eleitl@lemmy.zip
        link
        fedilink
        English
        arrow-up
        0
        ·
        9 days ago

        I know it because it’s in the spec necessary for licensing. It shuts off in under 20 ms so you can’t even get shocked by the prongs of the plug if pulled out.

          • eleitl@lemmy.zip
            link
            fedilink
            English
            arrow-up
            0
            ·
            9 days ago

            It is a commercial product, connected to the grid via a standard schuko plug, sold in Germany. It has to be compliant with the local law to be sold legally.

            It all shouldn’t be so difficult to understand.

            • artyom@piefed.social
              link
              fedilink
              English
              arrow-up
              0
              ·
              9 days ago

              It has to be compliant with the local law to be sold legally.

              So you can’t buy raw solar panels or inverters in Germany?

              It all shouldn’t be so difficult to understand.

              It’s not, which is why I’m not sure why you’re struggling.

              • ExcessShiv@lemmy.dbzer0.com
                link
                fedilink
                English
                arrow-up
                0
                ·
                9 days ago

                So you can’t buy raw solar panels or inverters in Germany?

                Sure you can. Solar panels will be fried by grid voltage more or less immediately if you connect them directly to a wall socket and become useless.

                You cannot buy a PV inverter in Germany (entire EU really) that doesn’t automatically shut off if it doesn’t detect a frequency to sync against from it’s AC side, unless it can run off-grid in which case it has to disble the grid connection within the same 20ms.

                • artyom@piefed.social
                  link
                  fedilink
                  English
                  arrow-up
                  0
                  ·
                  9 days ago

                  You cannot buy a PV inverter in Germany (entire EU really) that doesn’t automatically shut off if it doesn’t detect a frequency to sync against from it’s AC side, unless it can run off-grid in which case it has to disble the grid connection within the same 20ms.

                  So you can’t buy a grid-connected inverter with off-grid capabilities? Because the inverter has no way to tell the difference between the grid being off, and being off-grid.

                  • ExcessShiv@lemmy.dbzer0.com
                    link
                    fedilink
                    English
                    arrow-up
                    0
                    ·
                    9 days ago

                    Oh you can buy off grid inverters (or inverters capable of “island mode”). But they are required to be able to automatically disconnect from grid, even if they are never going to be connected to a grid. You can’t buy solar inverters without this for the exact reason that you can connect them to grid.

      • Resonosity@lemmy.dbzer0.com
        link
        fedilink
        English
        arrow-up
        0
        ·
        8 days ago

        Inverters in the US are all listed to UL1741-SB which dictates that they shall cease to energize their AC outputs if they sense an absence of grid voltage.

        Now, one thing people are ignoring is that UL1741-SB allows for islanding protection, and the disablement of it. If an inverter has its settings changed such that islanding protection is OFF, then the inverter will keep sending power to the “grid” because it thinks it’s operating on a microgrid that was previously disconnected from the larger grid via a Microgrid Interconnection Device (MID).

        The settings these inverters have are user-settable, which means they need to be checked by a qualified person, either a contractor, engineer, or inspector. These settings must also often be checked by the utility you’re interconnecting to before they allow you to energize, so usually all of these parties have eyes on the inverters’ settings and can stop work before energization until things are corrected.

        Ultimately I agree with you. If we don’t want to have to need inspections for every solar installation, especially residential ones and especially where plug-and-play solar modules are used, then inverters need to have their settings pre-configured for the grid code in the factory that then cannot be changed by the user or operator in the field. That would be a way to shoe-in this kind of installation.

        Hard setting grid codes into inverters prior to shipping to site might be overly conservative though, especially as utilities change their grid codes over time. You need to have a way to update those settings, which could be using a wireless portal hosted by the inverter OEM with credentials made only available to the OEM. Problem with this is that then you shift the burden of configuration to the manufacturer which already has a ton of other UL standards as well as rules and regulations to follow.

        What do y’all think?

        • Dozzi92@lemmy.world
          link
          fedilink
          English
          arrow-up
          1
          ·
          8 days ago

          I agree with everything you said except shoe-in, because it’s shoo-in.

          But you articulated (better than I was going to) the number one issue. Power companies need insurance and their insurance will be affected if ordinance permits basically unchecked generators being plugged into the grid. And before anyone says it, you are not allowed to just plug your generator into your house. Does it happen? Yeah, people have been dumb since day one.

          But there are transfer switches that allow for this operation in a safe manner, and the easiest way to deal with this is to have them installed by default in new construction, and to provide incentive for upgrading your panel to include one.

        • artyom@piefed.social
          link
          fedilink
          English
          arrow-up
          0
          ·
          8 days ago

          Inverters in the US are all listed to UL1741-SB which dictates that they shall cease to energize their AC outputs if they sense an absence of grid voltage.

          No, they are absolutely not. I don’t know where people are getting this idea. Many inverters aren’t even UL listed. There is absolutely no requirement for them to be. If that were the case, off-grid inverters wouldn’t even be allowed to exist. I own several that do not have this capability and are not UL listed.

          they need to be checked by a qualified person

          Not in the case of Utah’s new “balcony solar” laws. That’s the problem.

          which could be using a wireless portal hosted by the inverter OEM with credentials made only available to the OEM

          Oh goodie, I’ve always wanted DRM for my inverter.

          What do y’all think?

          I think it should just require a permit, like every other solar installation. Unless we can provide data to show that it’s not a problem in existing areas where this is common, and we research and follow their regulations.

          • Resonosity@lemmy.dbzer0.com
            link
            fedilink
            English
            arrow-up
            0
            ·
            8 days ago

            Many inverters aren’t even UL listed.

            Yes but many inspectors and insurance companies won’t want you to install electrical equipment on “real property” or buildings if it isn’t UL as that falls into the scope of AHJs and insurance providers. If there’s something that has the potential to start a fire, you need to have safety certifications so operating the system not only reduces the risk of fire, but also selling the house in the future to a new owner doesn’t come with excess burden on behalf of the next insurer.

            If your solar system is off-grid AND off-building, I see no reason that you need to have a UL listed system.

            This is of course dependent on local AHJs and utilities, but UL 1741 covers both standalone (off-grid) and grid-interactive (on-grid) inverters. If you’re choosing an inverter manufacturer that makes non-UL listed off-grid inverters, I would probably be suspect of their products’ quality as it’s easier to gain UL listing regardless of how the inverter is used: off-grid or grid-interactive.

            That’s the problem.

            That is a problem. Off-grid inverters that aren’t certified to UL 1741-SB aren’t required to have anti-islanding protection that cuts the inverters off if there’s an absence of grid voltage. If a “balcony solar” inverter were to NOT cease to energize upon loss of grid and stay islanded, then voltage is introduced to the building’s/community’s shared local distribution system. If work were to be done on that portion of the distribution system or grid where lineman and wireman expect conductors to be de-energized, then you might have injuries as a result. Now, you may be able to say that lineman and wireman should always test for presence of voltage prior to doing work, and as a solar engineer I would absolutely expect folks to do this, but that’s not always the case. People cut corners. And in the event that certain crews cut corners, don’t check for voltage and investigate where the voltage source is, and start touching wires and introducing paths to ground, people can get seriously injured or die.

            You may think that because solar panels are current-limited that this fact protects workers in the event of becoming exposed to live voltage, but any combination of voltage and current can kill.

            I’ve always wanted DRM for my inverter.

            In the context of safety, this is a good thing. Skirting DRM on movies or TVs won’t mean you injure yourself or others or worse. Skirting inverter settings can cause inverters to operate in ways that are unintended, and could hurt people. These things are not the same, and it’s concerning that you can’t see the difference.

            Also, having locks on settings means that other bad actors are deterred from changing those settings maliciously, whether intentional or not.

            There is not substitute for a qualified person operating and maintaining an electrical system, regardless of voltage.

            I think it should just require a permit

            Agreed

            • artyom@piefed.social
              link
              fedilink
              English
              arrow-up
              0
              arrow-down
              1
              ·
              8 days ago

              Yes but many inspectors and insurance companies won’t want you

              …why would anyone care what those people want?

              if there’s something that has the potential to start a fire, you need to have safety certifications

              No you don’t.

              If your solar system is off-grid AND off-building, I see no reason that you need to have a UL listed system.

              You’re missing the point. Nothing is stopping anyone from installing off-grid inverters (or any inverter at all) in an on-grid system.

              I would probably be suspect of their products’ quality

              Have you ever looked at “top sellers” on Amazon? Most people do not care about quality, they just buy the cheapest shit possible.

              These things are not the same, and it’s concerning that you can’t see the difference.

              I see the difference, I just don’t care. It’s concerning that you can’t see the potential for exploitation, both from corporations and governments.

    • 4am@lemmy.zip
      link
      fedilink
      English
      arrow-up
      0
      ·
      9 days ago

      What happens when someone makes an unsafe backfeed into a downed grid and then other nearby inverters detect the current and bring themselves back online? Is there a way to detect if the load is being delivered from the utility vs from incorrectly configured solar or generator installations?

      Some others are arguing back and forth about this elsewhere in the thread and I see the reasoning: unpermitted systems could accidentally energize isolated portions of the grid during downtime, which might trick properly installed systems to also come back online, and you have a runaway effect where there is enough current present to allow addition safety systems to be fooled.

      There isn’t any data transmission over the wires; there either is current, or there isn’t. Arguing over permitting is moot - either safety systems can handle this scenario already, or they can’t.

      All paperwork does is slow the relief of dependence on the utility, which hurts their profits.

      • atomicbocks@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        0
        ·
        9 days ago

        The same thing that currently happens when somebody does that with a gas generator? Linepersons get zapped… people get sued… etc…

        There isn’t any data transmission over the wires…

        That’s very wrong. Not only can you extend Ethernet in your own home using your power outlets, the power companies have been reading meters this way for decades.

        • artyom@piefed.social
          link
          fedilink
          English
          arrow-up
          0
          ·
          9 days ago

          Linepersons get zapped… people get sued… etc…

          Kinda seems like something you might want to avoid…

    • CMahaff@lemmy.world
      link
      fedilink
      English
      arrow-up
      0
      ·
      9 days ago

      Hmmm, I wonder how this would affect things in the future where this is widely used.

      I.E. if you had both widespread solar usage and some kind of large blackout, would it be hard to get all your solar back online because it’s all in the “waiting for the grid” state? And the grid can’t come back at capacity because all the solar it’s expecting is out?

      I assume people smarter than me have this figured out, but just a random thought if anyone knows more.